S8FS-C

S8FS-C

  • OMRON S8FS-C Power Supply ensures stability in challenging environments
  • Withstands abnormal voltages up to 300 VAC
  • Improved noise resistance, particularly from inverters and motors
  • 1.5 times lightning surge resistance, exceeding standard value

Download Catalog Click Here!

Harga terbaik
Tersedia layanan instalasi

Tersedia layanan maintenance

Garansi 1 tahun

Gratis Konsultasi

S8FS-C

  • OMRON S8FS-C Power Supply ensures stability in challenging environments
  • Withstands abnormal voltages up to 300 VAC
  • Improved noise resistance, particularly from inverters and motors
  • 1.5 times lightning surge resistance, exceeding standard value

Download Catalog Click Here!

  • OMRON S8FS-C Power Supply ensures stability in challenging environments
  • Withstands abnormal voltages up to 300 VAC
  • Improved noise resistance, particularly from inverters and motors
  • 1.5 times lightning surge resistance, exceeding standard value

Download Catalog Click Here!

Product Description

The OMRON S8FS-C Power Supply ensures stable equipment operation in challenging environments with features like resistance to abnormal voltages up to 300 VAC, improved noise resistance, and 1.5 times lightning surge resistance. With meticulous design and manufacturing, it guarantees reliability, maintaining a 38-year track record of excellence in power supply solutions for uninterrupted equipment performance.

‎ ‎ ‎ ‎ ‎

Ratings, Characteristics, and Functions

 

Power rating15 W
Output voltage (VDC)5 V12 V15 V24 V
Efficiency *115 VAC input80% typ.84% typ.84% typ.85% typ.
230 VAC input82% typ.85% typ.86% typ.87% typ.
InputVoltage range *Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC
input is the positive side and safety standards do not apply.) (Derating is
required according to the input voltage. Refer to Derating Curves on
Data Sheet.)
Frequency *50 /60 Hz (47 to 450 Hz)
Current *115 VAC input0.3 A typ.
230 VAC input0.19 A typ.
Power factor
Leakage
current
115 VAC input0.05 mA0.05 mA0.05 mA0.05 mA
230 VAC input0.10 mA0.10 mA0.10 mA0.10 mA
Inrush
current *
(for a cold
start at 25°)
115 VAC input16 A typ.
230 VAC input32 A typ.
OutputRated Output Current3 A1.3 A1 A0.7 A
Voltage adjustment range *-10% to 10% (with V. ADJ)
Ripple & Noise
voltage *
100 to 240
VAC input
30 mVp-p max.30 mVp-p max.40 mVp-p max.30 mVp-p max.
Input variation influence *0.5% max.
Load variation influence *1.0% max.
Temperature
variation
influence
100 to 240
VAC input
0.03%/°C max.
Startup
time *
115 VAC input490 ms typ.500 ms typ.470 ms typ.480 ms typ.
230 VAC input470 ms typ.480 ms typ.450 ms typ.460 ms typ.
Hold time *115 VAC input14 ms typ.16 ms typ.18 ms typ.15 ms typ.
230 VAC input83 ms typ.87 ms typ.92 ms typ.79 ms typ.
Addi-
tional
func-
tions
Overload protectionYes, automatic reset
Overvoltage protection *Yes, 115% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again)
Overheat protectionNo
Series operationYes (For up to 2 Power Supplies, external diodes are required.)
Parallel operationNo (However, backup operation is possible, external diodes are required.)
Remote sensingNo
Remote controlNo
Output indicatorYes (LED: Green)
Insula-
tion
Withstand voltage3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA
2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA
1 kVAC for 1 min. (between all output terminals and PE terminals) current
cutoff 20 mA
Insulation resistance100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC
Envi-
ron-
ment
Ambient operating temperature-20 to 60°C (Derating is required according to the temperature. Refer
to Derating Curves on Data Sheet.) (with no condensation or icing)
Storage temperature-40 to 85°C (with no condensation or icing)
Ambient operating humidity20% to 90% (Storage humidity: 10% to 95%)
Vibration resistance10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z
directions
10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z
directions
Shock resistance150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Relia-
bility
MTBF135,000 hrs min.
Life expectancy *10 years min.
Con-
struc-
tion
Dimensions (W × H × D)Refer to Dimensions.
Weight150 g max.
Cooling fanNo
Degree of protection
Stan-
dards
Harmonic current emissionsConforms to EN 61000-3-2, GB17625.1
EMIConducted
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
Radiated
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
EMSConforms to EN 61204-3 high severity levels
Safety StandardsApproved Standards
UL: cURus UL 62368-1 (Recognition) OVC II Pol2
CSA: cURus C22.2 No62368-1
CCC: GB4943
Conformed Standards
EN: EN 62368-1 OVC II Pol2
RCM (EN61000-6-4)
Marine StandardsNo
SEMINo

 

* Refer to Conditions of below.

 

Power rating25 W
Output voltage (VDC)5 V12 V15 V24 V
Efficiency *115 VAC input80% typ.84% typ.85% typ.86% typ.
230 VAC input82% typ.86% typ.88% typ.88% typ.
InputVoltage range *Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC
input is the positive side and safety standards do not apply.) (Derating is
required according to the input voltage. Refer to Derating Curves on
Data Sheet.)
Frequency *50 /60 Hz (47 to 450 Hz)
Current *115 VAC input0.49 A typ.
230 VAC input0.3 A typ.
Power factor
Leakage
current
115 VAC input0.10 mA0.10 mA0.10 mA0.10 mA
230 VAC input0.20 mA0.20 mA0.20 mA0.20 mA
Inrush
current *
(for a cold
start at 25°)
115 VAC input16 A typ.
230 VAC input32 A typ.
OutputRated Output Current5 A2.1 A1.7 A1.1 A
Voltage adjustment range *-10% to 10% (with V. ADJ)
Ripple & Noise
voltage *
100 to 240
VAC input
20 mVp-p max.20 mVp-p max.30 mVp-p max.40 mVp-p max.
Input variation influence *0.5% max.
Load variation influence *1.0% max.
Temperature
variation
influence
100 to 240
VAC input
0.03%/°C max.
Startup
time *
115 VAC input390 ms typ.340 ms typ.400 ms typ.360 ms typ.
230 VAC input360 ms typ.350 ms typ.400 ms typ.360 ms typ.
Hold time *115 VAC input17 ms typ.22 ms typ.23 ms typ.21 ms typ.
230 VAC input103 ms typ.113 ms typ.117 ms typ.112 ms typ.
Addi-
tional
func-
tions
Overload protectionYes, automatic reset
Overvoltage protection *Yes, 115% or higher of rated output voltage, power shut off (shut off the
input voltage and turn on the input again)
Overheat protectionNo
Series operationYes (For up to 2 Power Supplies, external diodes are required.)
Parallel operationNo (However, backup operation is possible, external diodes are required.)
Remote sensingNo
Remote controlNo
Output indicatorYes (LED: Green)
Insula-
tion
Withstand voltage3 kVAC for 1 min. (between all input terminals and output terminals)
current cutoff 20 mA
2 kVAC for 1 min. (between all input terminals and PE terminals) current
cutoff 20 mA
1 kVAC for 1 min. (between all output terminals and PE terminals) current
cutoff 20 mA
Insulation resistance100 MΩ min. (between all output terminals and all input terminals/PE
terminals) at 500 VDC
Envi-
ron-
ment
Ambient operating temperature-20 to 60°C (Derating is required according to the temperature. Refer
to Derating Curves on Data Sheet.) (with no condensation or icing)
Storage temperature-40 to 85°C (with no condensation or icing)
Ambient operating humidity20% to 90% (Storage humidity: 10% to 95%)
Vibration resistance10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z
directions
10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z
directions
Shock resistance150 m/s2, 3 times each in ±X, ±Y, ±Z directions
Relia-
bility
MTBF135,000 hrs min.
Life expectancy *10 years min.
Con-
struc-
tion
Dimensions (W × H × D)Refer to Dimensions.
Weight250 g max.
Cooling fanNo
Degree of protection
Stan-
dards
Harmonic current emissionsConforms to EN 61000-3-2, GB17625.1
EMIConducted
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
Radiated
Emissions
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254
EMSConforms to EN 61204-3 high severity levels
Safety StandardsApproved Standards
UL: cURus UL 62368-1 (Recognition) OVC II Pol2
CSA: cURus C22.2 No62368-1
CCC: GB4943
Conformed Standards
EN: EN 62368-1 OVC II Pol2
RCM (EN61000-6-4)
Marine StandardsNo
SEMINo

 

* Refer to Conditions of below.

 

Power rating35 W
Output voltage (VDC)5 V12 V15 V24 V
Efficiency *115 VAC input81% typ.83% typ.84% typ.87% typ.
230 VAC input81% typ.84% typ.84% typ.87% typ.
InputVoltage range *Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC
input is the positive side and safety standards do not apply.) (Derating is
required according to the input voltage. Refer to Derating Curves on
Data Sheet.)
Frequency *50 /60 Hz (47 to 450 Hz)
Current *115 VAC input0.66 A typ.
230 VAC input0.41 A typ.
Power factor
Leakage
current
115 VAC input0.15 mA0.15 mA0.15 mA0.15 mA
230 VAC input0.30 mA0.25 mA0.25 mA0.25 mA
Inrush
current *
(for a cold
start at 25°)
115 VAC input16 A typ.
230 VAC input32 A typ.
OutputRated Output Current7 A3 A2.4 A1.5 A
Voltage adjustment range *
    Harga terbaik
    Tersedia layanan instalasi

    Tersedia layanan maintenance

    Garansi 1 tahun

    Gratis Konsultasi

    Jaminan Original

    Elmecon Multikencana distributor resmi berbagai brand ternama

    30 Hari Pengembalian

    Gratis pengembalian produk selama 30 hari setelah pemasangan

    Pengiriman Seluruh Indonesia

    Mencakup pengiriman keseluruh kota di Indonesia

    100% Aman

    Mulai dari pemesanan, pembayaran, pengiriman hingga instalasi.

    Ada Kebutuhan Besar untuk Proyek Anda?

    Konsultasi gratis bersama tim Engineer berpengalaman kami serta dapatkan penawaran terbaik hanya untuk Anda.