F3SJ Series
- Enhanced Safety: Fixed response time, muting functions, and finger protection ensure comprehensive safety measures.
- Streamlined Installation: One-touch brackets and reduced wiring cut installation time by half.
- Simplified Operation: Intuitive diagnostics, easy-to-view indicators, and global support maximize productivity.
- Versatile Functionality: From basic detection to advanced muting and blanking functions, adapt to diverse environments effortlessly.
Download Catalog Click Here!
Product Description
The OMRON F3SJ Series encompasses a range of safety light curtains engineered to deliver top-notch safety functionality alongside simplified installation and operation. With three specialized types – EASY, BASIC, and ADVANCED – this series caters to diverse safety requirements with precision and efficiency.
Main Units
F3SJ-E[][][][]P25/N25
Model | PNP output | F3SJ-E[][][][]P25 |
---|---|---|
NPN output | F3SJ-E[][][][]P25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25 mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 54 | |
Protective height (PH) | 185 to 1,105 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time (under stable light incident condition) |
ON to OFF | 15 ms max. |
OFF to ON | 70 ms max. | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption current (no load) |
PNP output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max. Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams: 51 mA max. |
NPN output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams: 63 mA max. Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams: 48 mA max. |
|
Light source (emitted wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle (EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over |
|
Safety outputs (OSSD) |
PNP output | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output | Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Output operation mode | Safety output: On when receiving light | |
Input voltage | PNP output | Test input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 |
NPN output | Test input: ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA) OFF voltage: 1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5 |
|
Mutual interference prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Test function | Self test (at power-ON and at power distribution) External test (emission stop function by test input) |
|
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
|
Shock resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
|
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable | Connection method: Pull-out type, cable length 3 m Number of wires: Emitter: 5 wires, receiver: 6 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. *6 | |
Material | Case: Aluminum Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Net Weight *7 | Weight (g) = (protective height) x 1.59 + 330 | |
Gross Weight *8 | Weight (g) = (protective height) x 2.6 + 800 | |
Accessories | Instruction Manual, Quick Installation Manual (QIM) *9 | |
Applicable standards *10 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User’s Manual (SCHG-733/732).
*7. The net weight is the weight of an emitter and a receiver.
*8. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*9. Mounting brackets and test rod are sold separately.
*10.Refer to Safety Precautions for information about Legislation and Standards.
Indicator
Emitter
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
— |
Stable-state indicator |
STB | Turns ON when incidence level is more than 170% of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a lockout on the receiver. |
Blinks when the F3SJ-E enters a lockout on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter is ON. |
Blinks when the F3SJ-E enters a lockout due to power voltage/noise. |
Test indicator | TEST | — | Blinks when external test is being performed. |
Bottom-beam- state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
— |
Receiver
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
— |
Stable-state indicator |
STB | Turns ON when incidence level is more than 170% of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a lockout on the emitter. |
Blinks when the F3SJ-E enters a lockout on the receiver. |
Communication indicator |
COM | Turns ON when communication between emitter and receiver is established. |
Blinks when the F3SJ-E enters lockout due to a communication error between receiver and emitter. |
Configuration indicator |
CFG | — | Blinks when the F3SJ-E enters lockout due to a model type error between receiver and emitter. |
Internal error indicator |
INTERNAL | — | Blinks when the F3SJ-E enters a lockout due to an internal error. |
Bottom-beam- state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
— |
Accessories
Laser Pointer
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life * | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2, EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C, Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum, Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3), instruction manual |
* Battery life varies depending on a battery used.
F3SJ-B
Main Units
F3SJ-B[][][][]P25/N25
Model | PNP output | F3SJ-B[][][][]P25 |
---|---|---|
NPN output | F3SJ-B[][][][]N25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 102 | |
Protective height (PH) | 185 to 2,065 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time (under stable light incident condition) |
ON to OFF | 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) |
OFF to ON | 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption current (no load) |
PNP output | Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. Receiver: Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max. |
NPN output | Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. Receiver: Up to 22 beams: 47 mA max., 26 to 42 beams: 52 mA max., 46 to 62 beams: 58 mA max., 66 to 82 beams: 63 mA max., 86 to 102 beams: 69 mA max. |
|
Light source (emitted wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle (EAA) |
Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the detection distance is 3 m or over |
|
Safety outputs (OSSD) |
PNP output | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output | Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Auxiliary output |
PNP output | One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
NPN output | One NPN transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
|
Output operation mode | Safety output: On when receiving light Auxiliary output: – Reverse output of safety output for a basic system – ON when muting/override for a muting system |
|
Input voltage | PNP output | Test input, Interlock select input, Reset input, Muting input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5, OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5, OFF voltage: open |
NPN output | Test input, Interlock select input, Reset input, Muting input: ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA), OFF voltage:1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5 External device monitoring input: ON voltage: 0 to 3 V (short circuit current: approx. 5.5 mA) *5, OFF voltage: open |
|
Mutual interference prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Series connection | Time division emission by series connection • Number of connections: up to 3 sets (between F3SJ-Bs only)Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39- JBR2W) and power cable) |
|
Test function | • Self test (at power-ON and at power distribution) • External test (emission stop function by test input) |
|
Safety-related functions | • Interlock (basic system) • External device monitoring (basic system) • Muting (muting system) • Override (muting system) |
|
Connection type | Connector method (M12, 8-pin) | |
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
|
Shock resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
|
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable | Connection method: Prewired connector cable, cable length 0.3 m, connector type (M12, 8-pin), connector: IP67 rated (when mated) Number of wires: 8 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. | |
Material | Case: Aluminum Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Net Weight *6 | Weight (g) = (protective height) x 1.62 + 110 | |
Gross Weight *7 | Weight (g) = (protective height) x 2.7 + 500 | |
Accessories | Instruction Manual, Quick Installation Manual (QIM) *8 | |
Applicable standards *9 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as
capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. The net weight is the weight of an emitter and a receiver.
*7. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*8. Mounting brackets are sold separately.
*9. Refer to Safety Precautions for information about Legislation and Standards.
Indicator (F3SJ-B[][][][]P25/N25)
Emitter
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
Blinks during muting/override, or when cap error or connection error occurs. |
Stable-state indicator |
STB | Turns ON when incidence level is more than 170% of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter is ON. |
Blinks when the F3SJ-B enters a lockout due to power voltage/noise. |
Test indicator | TEST | — | Blinks when external test is being performed. |
Muting error indicator |
MUTING ERROR |
— | Blinks during a muting error. |
Muting input 1 indicator |
MUTE1 | Turns ON when muting input 1 is ON under the muting system. |
— |
Muting input 2 indicator |
MUTE2 | Turns ON when muting input 2 is ON under the muting system. |
— |
Bottom-beam-state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
Blinks during muting/override. |
Receiver
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
Blinks during muting/override, or when cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is more than 170% of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout on the receiver. |
Communication indicator |
COM | Turns ON when communication between emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout due to a communication error between receiver and emitter. |
Configuration indicator |
CFG | — | Blinks when the F3SJ-B enters lockout due to a model type error between receiver and emitter. |
Internal error indicator |
INTERNAL | — | Blinks when the F3SJ-B enters a lockout due to an internal error. |
Interlock indicator | INT -LK |
Turns ON when the F3SJ-B is in interlock state. |
Blinks when the F3SJ-B enters a lockout due to a wiring error. |
External device monitoring indicator |
EDM | Turns ON when an input is given to external device monitoring input. *1 *2 |
Blinks when the F3SJ-B enters a lockout due to an external device monitoring error. |
Bottom-beam-state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
Blinks during muting/override. |
monitoring.
*2. The meanings of the indicators are different for the models with the suffix “-01TS”. Refer to the F3SJ-B[][][][]P25-01TS
Safety Light Curtain User’s Manual (SCHG-734) or the specifications of the models with the suffix “-01TS”.
Main Units
F3SJ-B[][][][]P25-01TS/-02TS
Model | F3SJ-B[][][][]P25-01TS | F3SJ-B[][][][]P25-02TS | |
---|---|---|---|
Sensor type | Type 4 safety light curtain | ||
Setting tool connection *1 | Parameter settings: Not available | ||
Safety category | Safety purpose of category 4, 3, 2, 1, or B | ||
Detection capability | Opaque objects 25mm in diameter | ||
Beam gap (P) | 20 mm | ||
Number of beams (n) | 8 to 102 | 10 to 98 | |
Protective height (PH) | 185 to 2,065 mm | 225 to 1,985 mm | |
Lens diameter | Diameter 5 mm | ||
Operating range *2 | 0.2 to 7 m *2 | 0.2 to 6 m | |
Response time (under stable light incident condition) |
ON to OFF | 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | |
OFF to ON | 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | ||
Startup waiting time | 2 s max. | ||
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | ||
Consumption current (no load) |
Emitter | Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. |
Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 98 beams: 99 mA max. |
Receiver | Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max. |
Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 98 beams: 66 mA max. |
|
Light source (emitted wavelength) |
Infrared LED (870 nm) | ||
Effective aperture angle (EAA) |
Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the detection distance is 3 m or over |
||
Safety outputs (OSSD) | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
||
Auxiliary output | One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
||
Output operation mode | Safety output: On when receiving light Auxiliary output: Reverse output of safety output |
Safety output: On when receiving light Auxiliary output: • Basic system Reverse output of safety output • Muting system On during muting/override |
|
Input voltage | Test input ON voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 OFF voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 Reset input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5 OFF voltage: open |
Test input, Interlock select input, Reset input, Muting input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5 OFF voltage: open |
|
Mutual interference prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | ||
Series connection | Time division emission by series connection • Number of connections: up to 3 sets (between F3SJ-B[][][][]P25-01TSs only) Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39-JBR2W) and power cable) |
Time division emission by series connection • Number of connections: up to 3 sets (between F3SJ-B[][][][] P25-02TSs only) Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39-JBR2W) and power cable) |
|
Test function | • Self test (at power-ON and at power distribution) • External test (emission stop function by test input) |
||
Safety-related functions | External device monitoring | External device monitoring (basic system) Muting (muting system) Override (muting system) |
|
Connection type | Connector method (M12, 8-pin) | ||
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | ||
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | ||
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | ||
Operating ambient light intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | ||
Degree of protection | IP65 (IEC 60529) | ||
Vibration resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
||
Shock resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
||
Pollution degree | Pollution degree 3 (IEC 60664-1) | ||
Power cable | Connection method: Prewired connector cable, cable length 0.3 m, connector type (M12, 8-pin), connector: IP67 rated (when mated) Number of wires: 8 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
||
Extension cable | 30 m max. | ||
Material | Case: Aluminum Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
||
Net Weight *6 | Weight (g) = (protective height) x 1.62 + 110 |
Weight (g) = (protective height) x 1.83 + 122 |
|
Gross Weight *7 | Weight (g) = (protective height) x 2.7 + 500 | Weight (g) = (protective height) x 2.9 + 550 | |
Accessories | Quick Installation Manual (QIM), Instruction Manual *8 | ||
Applicable standards *9 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
Light Curtain User’s Manual (SCHG-734) for details.
2. Reset mode is fixed with auto reset mode.
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as
capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. The net weight is the weight of an emitter and a receiver.
*7. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*8. Mounting brackets and test rod are sold separately.
*9. Refer to Safety Precautions for information about Legislation and Standards.
Indicator (F3SJ-B[][][][]P25-01TS)
Emitter
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
Blinks when cap error or connection error occurs. |
Stable-state indicator |
STB | Turns ON when incidence level is 170% or more of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter is ON. |
Blinks when the F3SJ-B enters a lockout due to power voltage/noise. |
Test indicator | TEST | — | Blinks when external test is being performed. |
Bottom-beam-state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
— |
Receiver
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
Blinks when cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170% or more of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout on the receiver. |
Communication indicator |
COM | Turns ON when communication between emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout due to a communication error between receiver and emitter. |
Configuration indicator |
CFG | — | Blinks when the F3SJ-B enters lockout due to a model type error between receiver and emitter. |
Internal error indicator |
INTERNAL | — | Blinks when the F3SJ-B enters a lockout due to an internal error. |
Interlock indicator | INT -LK |
Not used | Not used |
External device monitoring indicator |
EDM | Turns ON when an input is given to external device monitoring input. * |
Blinks when the F3SJ-B enters a lockout due to an external device monitoring error. |
Bottom-beam-state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
— |
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
Indicator (F3SJ-B[][][][]P25-02TS)
Emitter
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
Blinks during muting/override, or when cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170% or more of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter is ON. |
Blinks when the F3SJ-B enters a lockout due to power voltage/noise. |
Test indicator | TEST | — | Blinks when external test is being performed. |
Muting error indicator | MUTING ERROR |
— | Blinks during a muting error. |
Muting input 1 indicator |
MUTE1 | Turns ON when muting input 1 is ON under the muting system. |
— |
Muting input 2 indicator |
MUTE2 | Turns ON when muting input 2 is ON under the muting system. |
— |
Bottom-beam-state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
Blinks during muting/override. |
Receiver
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state indicator |
TOP | Turns ON when the top beam is receiving light. |
Blinks during muting/override, or when cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170% or more of the output ON threshold. |
Blinks when the safety output is turned OFF due to disturbance light or vibration. |
ON/OFF-state indicator |
ON OFF |
Green: Turns ON when safety output is ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout on the receiver. |
Communication indicator |
COM | Turns ON when communication between emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout due to a communication error between receiver and emitter. |
Configuration indicator |
CFG | — | Blinks when the F3SJ-B enters lockout due to a model type error between receiver and emitter. |
Internal error indicator |
INTERNAL | — | Blinks when the F3SJ-B enters a lockout due to an internal error. |
Interlock indicator | INT -LK |
Not used | Not used |
External device monitoring indicator |
EDM | Turns ON when an input is given to external device monitoring input. * |
Blinks when the F3SJ-B enters a lockout due to an external device monitoring error. |
Bottom-beam-state indicator |
BTM | Turns ON when the bottom beam is receiving light. |
Blinks during muting/override. |
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
Accessories
Control Unit
Model | F3SP-B1P | |
---|---|---|
Applicable sensor | F3SJ-B/A (Only for PNP output type) * | |
Power supply voltage | 24 VDC±10% | |
Power consumption | DC1.7 W max. (not including sensor’s current consumption) | |
Operation time | 100 ms max. (not including sensor’s response time) | |
Response time | 100 ms max. (not including sensor’s response time) | |
Relay output | Number of contacts | 3NO+1NC |
Rated load | 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms | |
Rated current | 5 A | |
Connection type | Between sensors | M12 connector (8-pin) |
Others | Terminal block | |
Weight (packed state) | Approx. 280 g | |
Accessories | Instruction manual |
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Laser Pointer
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series *1 |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life *2 | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2, EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3), instruction manual |
*1. It cannot be mounted to the models with the suffix “-02TS”.
*2. Battery life varies depending on a battery used.
F3SJ-A
Main Units
F3SJ-A[][][][]P14/P20/P30/P55/N14/N20/N30/N55
Model | PNP outputs |
F3SJ-A[][][][]P14 | F3SJ-A[][][][]P20 | F3SJ-A[][][][]P30 | F3SJ-A[][][][]P55 |
---|---|---|---|---|---|
NPN outputs |
F3SJ-A[][][][]N14 | F3SJ-A[][][][]N20 | F3SJ-A[][][][]N30 | F3SJ-A[][][][]N55 | |
Sensor type | Type 4 safety light curtain | ||||
Version | Ver. 2 | ||||
Setting tool connection | Connectable | ||||
Safety category | Safety purpose of category 4, 3, 2, 1, or B | ||||
Detection capability | Opaque objects 14 mm in diameter |
Opaque objects 20 mm in diameter |
Opaque objects 30 mm in diameter |
Opaque objects 55 mm in diameter |
|
Beam gap (P) | 9 mm | 15 mm | 25 mm | 50 mm | |
Number of beams (n) | 26 to 140 | 16 to 100 | 10 to 100 | 6 to 50 | |
Protective height (PH) | 245 to 1,271 mm | 245 to 1,505 mm | 245 to 2,495 mm | 270 to 2,470 mm | |
Lens diameter | Diameter 5 mm | ||||
Operating range * | 0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.) (Depending on the setting tool, the detection distance can be shortened to 0.5 m.) |
||||
Response time (under stable light incident condition) (For details, see “Response Time” on Catalog.) |
ON to OFF | 1 set, 0245 to 983: 11 ms to 17.5 ms max. 1,055 or higher: 20 ms to 25 ms max. |
1 set, 0245 to 1205: 10 ms to 15 ms max. 1235 or higher: 17.5 ms to 22.5 ms max. |
1 set: 10 ms to 17.5 ms max. |
1 set: 10 ms to 13 ms max. |
OFF to ON | 1 set, 0245 to 983: 44 ms to 70 ms max. 1,055 or higher: 80 ms to 100 ms max. |
1 set, 0245 to 1205: 40 ms to 60 ms max. 1235 or higher: 70 ms to 90 ms max. |
1 set: 40 ms to 70 ms max. |
1 set: 40 ms to 52 ms max. |
|
Startup waiting time | 2 s max. (2.2 s max. for series connection) | ||||
Power supply voltage (Vs) | 24 VDC ±20% (ripple p-p10% max.) | ||||
Current consumption (no load) |
Emitter | To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max., 151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max. |
|||
Receiver | To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max., 151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max. |
||||
Light source (emitted wavelength) |
Infrared LED (870 nm) | ||||
Effective aperture angle (EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection distance is 3 m or over |
||||
Safety outputs (OSSD) |
PNP outputs |
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), allowable capacity load 2.2 μF, leak current 1 mA max. (This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
|||
NPN Output |
Two NPN transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), allowable capacity load 2.2 μF, leak current 2 mA max. (This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
||||
Auxiliary output 1 (Non-safety output) |
PNP outputs |
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
|||
NPN Output |
One NPN transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
||||
Auxiliary output 2 (Non-safety output. Function for Basic System.) |
PNP outputs |
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
|||
NPN Output |
One NPN transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max. |
||||
External indicator output (Non-safety output) |
Available indicators • Incandescent lamp: 24 VDC, 3 to 7 W • LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max. (To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.) |
||||
Output operation mode |
Receiver | Safety output 1, 2: ON when receiving light Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.) External indicator output 1: Inverse of safety output signals for a basic system (Operation mode can be changed with the setting tool.), ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
|||
Emitter | Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed with the setting tool.) External indicator output 2: ON when lock-out for a basic system (Operation mode can be changed with the setting tool.) ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
||||
Input voltage |
PNP output |
Test input, Interlock select input, Reset input, Muting input: ON voltage: 9 V to Vs (short circuit current: approx. 2.0 mA), OFF voltage: 0 to 1.5 V, or open External device monitoring input: ON voltage: 9 V to Vs (short circuit current: approx. 3.5 mA), OFF voltage:open Note: The Vs indicates a voltage value in your environment. |
|||
NPN output |
Test input, Interlock select input, Reset input, Muting input: ON voltage: 0 to 1.5 V (short-circuit current: approx. 1.5 mA), OFF voltage: 9 V to Vs, or open External device monitoring input: ON voltage: 0 to 1.5 V (short-circuit current: approx. 4.0 mA), OFF voltage:open Note: The Vs indicates a voltage value in your environment. |
||||
Indicator | Emitter | Light intensity level indicators (green LED x 2, orange LED x 3): ON based on the light intensity Error mode indicators (red LED x 3): Blink to indicate error details Power indicator (green LED x 1): ON while power is on Interlock indicator (yellow LED x 1): ON while under interlock, blinks at lockout. External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED x 2): ON/flash according to function |
|||
Receiver | Light intensity level indicators (green LED x 2, orange LED x 3): ON based on the light intensity Error mode indicators (red LED x 3): Blink to indicate error details OFF output indicator (red LED x 1): ON when safety output is OFF, blinks at lockout. ON output indicator (green LED x 1): ON while safety output is ON Muting error indicator, Blanking /test indicator (green LED x 2): ON/flash according to function |
||||
Mutual interference prevention function |
Interference light prevention algorithm, detection distance change function | ||||
Series connection | Time division emission by series connection • Number of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected. • Total number of beams: up to 400 beams • Cable length between sensors: 15 m max. (not including series connection cable (F39-JJR3W or F39-JJR[]L) and power cable) • Response time under connection: Refer to Catalog |
||||
Test function | • Self test (at power-ON and at power distribution) • External test (emission stop function by test input) |
||||
Safety-related functions | • Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.) • External device monitor • Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.) • Fixed blanking (must be set by a setting tool) • Floating blanking (must be set by a setting tool) |
||||
Connection method | Connector method (M12, 8-pin) | ||||
Protective circuits | Output short-circuit protection, and power supply reverse polarity protection | ||||
Ambient temperature | Operating: -10 to 55°C (no icing), Storage: -30 to 70°C | ||||
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% | ||||
Operating ambient light intensity |
Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving- surface light intensity of 10,000 lx max. |
||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Withstand voltage | 1,000 VAC 50/60 Hz, 1 min | ||||
Degree of protection | IP65 (IEC 60529) | ||||
Vibration resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, and Z directions (no delay at resonant frequencies) |
||||
Shock resistance | Class 3M4 (IEC TR 60721-4-3) Operation limit: Acceleration of 15 G, Pulse duration of 6 ms, 100 shocks for each in X, Y, and Z directions (600 shocks in total) |
||||
Materials | Casing (including metal parts on both ends): Aluminum, zinc die-cast Cap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC |
||||
Net Weight *1 | Calculate using the following expressions: (1) For F3SJ-A[][][][][]14, weight (g) = (protective height) x 1.67 + 215 (2) For F3SJ-A[][][][][]20, weight (g) = (protective height) x 1.5 + 217 (3) For F3SJ-A[][][][][]30, weight (g) = (protective height) x 1.41 + 220 (4) For F3SJ-A[][][][][]55, weight (g) = (protective height) x 1.3 + 220 |
||||
Gross Weight *1 | Calculate using the following expressions: (1) For F3SJ-A[][][][][]14, weight (g) = (protective height) x 1.7 + α (2) For F3SJ-A[][][][][]20/F3SJ-A[][][][][]30, weight (g) = (protective height) x 1.5 + α (3) For F3SJ-A[][][][][]55, weight (g) = (protective height) x 1.4 + α The values for α are as follows: Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400 Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600 Protected height 1,136 to 1,658 mm: = 2,000 |
||||
Accessories | Instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets (intermediate) (*), error mode label, Quick Installation Manual (QIM) *. Number of intermediate brackets depends on protective height of F3SJ. • For protective height from 600 to 1,130 mm: 1 set for each of the emitter and receiver is included • For protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are included • For protective height from 1,660 to 2,180 mm: 3 sets for each of the emitter and receiver are included • For protective height from 2,195 to 2,500 mm: 4 sets for each of the emitter and receiver are included |
||||
Applicable standards *3 | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment) IEC 61496-2, EN 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
* Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*1. The net weight is the weight of an emitter and a receiver.
*2. The gross weight is the weight of an emitter, a receiver, included accessories and a package.
*3. Refer to Safety Precautions for information about Legislation and Standards.
Response Time
Model | Protected Height (mm) |
Number of Beams | Response time ms (ON to OFF) |
Response time ms (OFF to ON) |
---|---|---|---|---|
F3SJ-A[]14 Series | 245 to 263 | 26 to 28 | 11 | 44 |
281 to 389 | 30 to 42 | 12 | 48 | |
407 to 497 | 44 to 54 | 13 | 52 | |
515 to 605 | 56 to 66 | 14 | 56 | |
623 to 731 | 68 to 80 | 15 | 60 | |
767 to 983 | 84 to 108 | 17.5 | 70 | |
1,055 to 1,271 | 116 to 140 | 20 | 80 | |
F3SJ-A[]20 Series | 245 | 16 | 10 | 40 |
275 to 425 | 18 to 28 | 11 | 44 | |
455 to 635 | 30 to 42 | 12 | 48 | |
665 to 815 | 44 to 54 | 13 | 52 | |
845 to 995 | 56 to 66 | 14 | 56 | |
1,025 to 1,205 | 68 to 80 | 15 | 60 | |
1,235 to 1,505 | 82 to 100 | 17.5 | 70 | |
F3SJ-A[]30 Series | 245 to 395 | 10 to 16 | 10 | 40 |
420 to 720 | 17 to 29 | 11 | 44 | |
745 to 1,045 | 30 to 42 | 12 | 48 | |
1,070 to 1,295 | 43 to 52 | 13 | 52 | |
1,395 to 1,620 | 56 to 65 | 14 | 56 | |
1,745 to 1,995 | 70 to 80 | 15 | 60 | |
2,120 to 2,495 | 85 to 100 | 17.5 | 70 | |
F3SJ-A[]55 Series | 270 to 770 | 6 to 16 | 10 | 40 |
820 to 1,420 | 17 to 29 | 11 | 44 | |
1,470 to 2,070 | 30 to 42 | 12 | 48 | |
2,120 to 2,470 | 43 to 50 | 13 | 52 |
Use the following expressions for series connection.
For 2-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit – 1 (ms), Response time (OFF
to ON): Response time calculated by the above x 4 (ms)
For 3-set series connection:
Response time (ON to OFF):
Response time of the 1st unit + Response time of the 2nd unit + Response time of 3rd unit – 5 (ms), Response time (OFF
to ON): Response time calculated by the above x 5 (ms)
(For models with the “-TS” suffix, multiply the response time obtained by the above x 5 (ms), or use 200 ms, whichever
is less.)
For 4-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit + Response time of the 3rd
unit + Response time of the 4th unit – 8 (ms)
Response time (OFF to ON): Response time calculated by the above x 5 (ms)
Cable Extension Length
Total cable extension length must be no greater than the lengths described below.
When the F3SJ and an external power supply are directly connected, or when the F3SJ is connected to a G9SA-300-SC.
Condition | 1 set | 2 sets | 3 sets | 4 sets |
---|---|---|---|---|
Using incandescent lamp for auxiliary output and external indicator output | 45 m | 40 m | 30 m | 20 m |
Not using incandescent lamp * | 100 m | 60 m | 45 m | 30 m |
When connected to the F3SP-B1P
Condition | 1 set | 2 sets | 3 sets | 4 sets |
---|---|---|---|---|
Using incandescent lamp for external indicator output 2 | 40 m | 30 m | 25 m | 20 m |
Using incandescent lamp for external indicator output 1 | 60 m | 45 m | 30 m | 20 m |
Using incandescent lamp for auxiliary output 1 | ||||
Not using incandescent lamp * | 100 m | 60 m | 45 m | 30 m |
operating normally.
* The F39-A01P[]-PAC Dedicated External Indicator Set uses LEDs. Refer to the cable extension lengths for “Not using
incandescent lamp”.
Accessories
Control Unit
Model | F3SP-B1P | |
---|---|---|
Applicable sensor | F3SJ-B/A (Only for PNP output type) * | |
Power supply voltage | 24 VDC±10% | |
Power consumption | DC1.7 W max. (not including sensor’s current consumption) | |
Operation time | 100 ms max. (not including sensor’s response time) | |
Response time | 10 ms max. (not including sensor’s response time) | |
Relay output | Number of contacts | 3NO+1NC |
Rated load | 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms | |
Rated current | 5 A | |
Connection type | Between sensors | M12 connector (8-pin) |
Others | Terminal block | |
Weight (packed state) | Approx. 280 g | |
Accessories | Instruction manual |
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Laser Pointer
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life * | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2, EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3), instruction manual |
* Battery life varies depending on a battery used.
Dedicated External Indicator Set
Model | F39-A01PR-PAC | F39-A01PG-PAC | F39-A01PY-PAC |
---|---|---|---|
Applicable sensor | F3SJ-A (Common for PNP/NPN output type. Can be attached to emitters and/or receivers) | ||
Light source | Red LED | Green LED | Yellow LED |
Power supply voltage | 24 VDC±10% (supplied by sensor) | ||
Consumption current | 50 mA max. (supplied by sensor) | ||
Connection type | Dedicated accessory connector cable (Sensor side: Dedicated 10-pin connector, Indicator side: M12 8-pin connector) |
||
Set details | Indicator (red), Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Indicator (green), Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Indicator (yellow), Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Water-resistant Case
Model | F39-EJ[][][][]-L, F39-EJ[][][][]-D | |
---|---|---|
Applicable sensor | F3SJ-A Series Curtains with a protective height of 600 mm or shorter. |
F3SJ-A Series Curtains with a protective height of 605 mm or longer. |
Ambient temperature | -10 to 55°C (operation and storage) | 13 to 33°C (operation and storage) |
Mounting direction | No restrictions | Vertical direction only (see following diagram) |
Operating range | 0.2 to 7 m (for a protective height of 1,631 mm max.), 0.2 to 5 m (for a protective height of 1,655 mm min.) |
|
Degree of protection | IP67 (IEC 60529) (When assembled according to the application precautions) | |
Material | Case: Acrylic resin, Rubber: Nitrile rubber, M5 bolt: SUSXM7, M4 bolt: SUS316L, Cable: Oil-resistant PVC, Plate: SUS304, Mounting Bracket (optional): SUS304 |
|
Weight (packed state) | Calculation formula: Weight (g) = 1.5 x [][][][] + 300 ([][][][] stands for the four digits of the model number (protective height)) (The optional Mounting Brackets come in a set of two, and weigh 120 g. This weight is not included in the above formula.) |
When using Curtains with a protective height of 605 mm or more, the vibration performance of the applicable
sensor is reduced.
Do not use these Curtains in locations that are subject to vibration.
2. Operating range
When using these cases, the operating range of the applicable sensor is reduced.
Check the specifications prior to use.
3. Mounting direction
When using Curtains with a protective height of 605 mm or more, some slackness occurs due to the weight
of the Curtain.
For this reason, mount these Curtains only in the vertical direction.