S8VS

S8VS

  • Status displayed on 3-digit, 7-segment display. *
  • Signal output notifications at 90 W or more. *
  • Conformity to various safety standards for global usability.
  • Varied coverage with 3-year warranty.
  • DIN rail mounting supported.

*) Models with indication monitor

Download Catalog Click Here!

Harga terbaik
Tersedia layanan instalasi

Tersedia layanan maintenance

Garansi 1 tahun

Gratis Konsultasi

S8VS

  • Status displayed on 3-digit, 7-segment display. *
  • Signal output notifications at 90 W or more. *
  • Conformity to various safety standards for global usability.
  • Varied coverage with 3-year warranty.
  • DIN rail mounting supported.

*) Models with indication monitor

Download Catalog Click Here!

  • Status displayed on 3-digit, 7-segment display. *
  • Signal output notifications at 90 W or more. *
  • Conformity to various safety standards for global usability.
  • Varied coverage with 3-year warranty.
  • DIN rail mounting supported.

*) Models with indication monitor

Download Catalog Click Here!

Product Description

The OMRON S8VS series offers an intuitive Indication Monitor, enhancing maintenance efficiency by providing clear visualization of the operating status. Equipped with a 3-digit, 7-segment display, it offers concise status updates. Signal output notifications activate at 90 W or higher, ensuring timely alerts. Compliant with various safety standards for global usability, it assures reliability across different regions. Backed by a 3-year warranty, it offers extensive coverage, promising peace of mind to users.

‎ ‎ ‎ ‎

Ratings/Characteristics

 

Power ratings15 W30 W
Output voltage (VDC)5 V12 V24 V5 V12 V24 V
EfficiencyWith 100-VAC input74% typical79% typical83% typical74% typical81% typical85% typical
With 200-VAC input73% typical78% typical80% typical74% typical80% typical86% typical
InputVoltage *1100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *5)
Frequency *150/60 Hz (47 to 450 Hz)
CurrentWith 100-VAC input0.45 A max., 0.34 A typical0.9 A max., 0.66 A typical
With 200-VAC input0.25 A max., 0.22 A typical0.6 A max., 0.4 A typical
Power factor *6
Harmonic current regulationConforms to EN61000-3-2
Leakage
current
With 100-VAC input0.5 mA max.
With 200-VAC input1.0 mA max.
Inrush
current
*2
With 100-VAC input17.5 A max., 14 A typical
With 200-VAC input35 A max., 28 A typical
OutputVoltage adjustment range *3– 10% to 15% (with V.ADJ)
Ripple noise voltage (at rated I/O)60 mV max.70 mV max.60 mV max.60 mV max.90 mV max.150 mV max.
Input variation influence0.5% max. (at 85- to 264-VAC input, 100% load)
Load variation influence
(rated input voltage)
2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load)
Temperature variation influence0.05%/°C max.
Startup time
(at rated I/O) *2
With 100-VAC input580 ms typical530 ms typical600 ms typical500 ms typical560 ms typical560 ms typical
With 200-VAC input340 ms typical360 ms typical400 ms typical360 ms typical380 ms typical400 ms typical
Output hold time
(at rated I/O) *2
With 100-VAC input39 ms typical27 ms typical28 ms typical31 ms typical22 ms typical31 ms typical
With 200-VAC input187 ms typical134 ms typical134 ms typical174 ms typical123 ms typical140 ms typical
Additional
functions
Overload protection *2The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Overvoltage protection *2Yes *4
Output voltage indicationNo
Output current indicationNo
Peak-hold current indicationNo
Maintenance forecast monitor indicationNo
Maintenance forecast monitor outputNo
Total run time monitor indicationNo
Total run time monitor outputNo
Undervoltage alarm indicationYes (color: red)
Undervoltage alarm outputNo
Parallel operationNo (However, backup operation is possible. An external diode is required.)
Series operationModels with 24-V output: Possible for up to 2 Power Supplies (with external diode)
Models with 5- or 12-V output: Not possible
OtherOperating ambient temperatureRefer to the derating curve in Engineering Data. (with no icing or condensation)
Storage temperature– 25 to 65°C
Operating ambient humidity25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Insulation resistance100 MΩ min. (between all outputs and all inputs/PE terminals) at 500 VDC
Vibration resistance10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
Shock resistance150 m/s2 , 3 times each in ±X, ±Y, and ±Z directions
Output indicatorYes (color: green)
EMIConducted EmissionsConforms to EN55011 Group1 Class B and based on FCC Class A
Radiated EmissionsConforms to EN55011 Group1 Class B
EMSConforms to EN61204-3 high severity levels
Approved standardsUL 508 (Listing, Class2 Output: Per 1310)
UL 62368-1
CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
CSA C22.2 No.62368-1 (cUR)
EN 62477-1, EN 62368-1
RCM mark
SEMIF47-0706 (With 200-VAC input)
Weight160 g max.180 g max.

 

 

*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but
the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on Data Sheet for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage
adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be
sure that the load is not damaged.
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*6. The value is when both rated output voltage and rated output current are satisfied.

 

 

Power ratings60 W
TypeStandardMaintenance forecast
monitor
Total run time
monitor
EfficiencyWith 100-VAC input84% typical83% typical
With 200-VAC input83% typical85% typical
InputVoltage *1100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *11)
Frequency *150/60 Hz (47 to 450 Hz)
CurrentWith 100-VAC input1.7 A max., 1.3 A typical1.7 A max., 1.3 A typical
With 200-VAC input1.0 A max., 0.68 A typical1.0 A max., 0.78 A typical
Power factor *12
Harmonic current regulationConforms to EN61000-3-2
Leakage currentWith 100-VAC input0.5 mA max.
With 200-VAC input1.0 mA max.
Inrush current *2With 100-VAC input17.5 A max., 14 A typical
With 200-VAC input35 A max., 28 A typical
OutputVoltage adjustment range *3-10% to 15% (with V. ADJ) (The voltage cannot be adjusted for the S8VS-09024[][][]S-[].)
Ripple noise voltage (at rated I/O)70 mV max.90 mV max.
Input variation influence0.5% max. (at 85- to 264-VAC input, 100% load)
Load variation influence (rated input voltage)1.5% max. (with rated input, 0 to 100% load)
Temperature variation influence0.05%/°C max.
Startup time
(at rated I/O) *2
With 100-VAC input620 ms typical460 ms typical
With 200-VAC input400 ms typical290 ms typical
Output hold time
(at rated I/O) *2
With 100-VAC input34 ms typical33 ms typical
With 200-VAC input158 ms typical154 ms typical
Additional
functions
Overload protection *2105% to 160% of rated load current (101% to 110% of rated load current for the S8VS-09024[][][]S-[]),
inverted L voltage drop, intermittent, automatic reset
Overvoltage protection *2, *4Yes
Output voltage indication *5NoYes (selectable) *6
Output current indication *5NoYes (selectable) *7
Peak-hold current indication *5NoYes (selectable) *8
Maintenance forecast monitor indication *5NoYes (selectable)No
Maintenance forecast monitor outputNo
Total run time monitor indication *5NoYes (selectable)
Total run time monitor output *5No
Undervoltage alarm indication *5NoYes (selectable)
Undervoltage alarm output terminalsNo
Parallel operationNo (However, backup operation is possible. An external diode is required.)
Series operationYes for up to 2 Power Supplies (with external diode)
OtherOperating ambient temperatureRefer to the derating curve in . (with no icing or condensation)
Storage temperature-25 to 65°C
Operating ambient humidity25% to 85% (Storage humidity: 25% to 90%)
Dielectric strength3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection
current for models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
Insulation resistance100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
Vibration resistance10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
Shock resistance150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Output indicatorYes (color: green)
EMIConducted
Emissions
Models with indication monitor: Conforms to EN55011 Group1 Class A and based on FCC Class A,
Conforms to EN55011 Group1 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Radiated
Emissions
Models with indication monitor: Conforms to EN55011 Group1 Class A, Conforms to EN55011 Group1 Class B *11
Standard models: Conforms to EN55011 Group1 Class B
EMSConforms to EN61204-3 high severity levels
Approved standards *11Standard model:
UL 508 (Listing; Class 2 Output: Per UL1310)
UL 62368-1
CSA C22.2 No.107.1 (cUL) (Class 2 Output: Per CSA C22.2 No. 223)
CSA C22.2 No.62368-1 (cUR)
EN 62477-1, EN 62368-1
RCM mark
With indication monitor:
UL 508 (Listing, Class2 Output: Per 1310)
CSA C22.2 No.107.1 (cUL) (Class2 Output: Per CSA C22.2 No.223)
EN 62477-1
RCM mark, KOSHA S Mark *10
SEMI *11F47-0706 (With 200-VAC input)
Weight330 g max.

 

*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on data sheet for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models with indication monitor).
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. Displayed on 7-segment LED. (character height: 8 mm)
*6. Resolution of output voltage indication: 0.1 V, Precision of output voltage indication: ±2% (percentage of output voltage value, ±1 digit)
*7. Resolution of output current indication: 0.1 A; Precision of output current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage)
*8. Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication: ±5% F.S. ±1 digit max. (specified by rated output voltage);
Signal width required for peak-hold current: 20 ms
*9. A Type and B Type: Sinking, AP Type and BP Type: Sourcing, BE Type: No alarm output.
*10. S8VS-06024A, S8VS-09024A/AP, S8VS-12024A/AP, S8VS-18024A/AP, and S8VS-24024A/AP only
*11. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*12. The value is when both rated output voltage and rated output current are satisfied.

 

Power ratings90 W
TypeStandardMaintenance forecast
monitor
Total run time
monitor
EfficiencyWith 100-VAC input83% typical83% typical
With 200-VAC input84% typical85% typical
InputVoltage *1100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *11)
Frequency *150/60 Hz (47 to 450 Hz)
CurrentWith 100-VAC input2.3 A max., 1.9 A typical2.3 A max., 1.9 A typical
With 200-VAC input1.4 A max., 1.0 A typical1.4 A max., 1.2 A typical
Power factor *12
Harmonic current regulation<

    Harga terbaik
    Tersedia layanan instalasi

    Tersedia layanan maintenance

    Garansi 1 tahun

    Gratis Konsultasi

    Jaminan Original

    Elmecon Multikencana distributor resmi berbagai brand ternama

    30 Hari Pengembalian

    Gratis pengembalian produk selama 30 hari setelah pemasangan

    Pengiriman Seluruh Indonesia

    Mencakup pengiriman keseluruh kota di Indonesia

    100% Aman

    Mulai dari pemesanan, pembayaran, pengiriman hingga instalasi.

    Ada Kebutuhan Besar untuk Proyek Anda?

    Konsultasi gratis bersama tim Engineer berpengalaman kami serta dapatkan penawaran terbaik hanya untuk Anda.